Property-local

Every tenant’s gateway runs on site

On a property that controls its own Ethernet, MaxLinear initiators reach NVIDIA BlueField-3 DPU concentrators in the building. Those concentrators host each tenant’s virtual gateway (vGW).

Cutaway of an apartment building. A red riser climbs from a ground-floor equipment rack to every floor, and two underground routes leave the building in opposite directions.
One rack, two separate routes out. Illustration.

How traffic flows

Traffic stays on the property until the last step.

How each tenant’s private network works
  1. Device to initiator

    A phone joins a MaxLinear SoC access point (AP) shared by many tenants.

  2. Into the tenant’s tunnel

    The AP encapsulates the phone’s traffic. In a VXLAN deployment, each tenant has its own VXLAN network identifier (VNI).

  3. Across property Ethernet

    Patch panels and stacked switches carry it, with no NAT.

  4. Into the concentrator

    A BlueField-3 DPU at the property headend terminates the tunnel.

  5. Through the tenant’s vGW

    The vGW applies the tenant’s firewall, NAT, bandwidth policy and public IP.

  6. Out to the Internet

    It leaves on one of two dedicated Internet access (DIA) uplinks.

Red and white patch cables connect rows of Ethernet switches and patch panels in a freestanding rack.

Why the private path matters

With no NAT on the path, GRE works naturally. On spine-leaf fabrics that need equal-cost multipath, VXLAN’s load distribution may justify its extra overhead.

Where the operator controls the switches, raising their MTU to 1,550 bytes keeps a full 1,500-byte inner packet under either protocol.

VXLAN versus GRE (white paper)

What runs where

Where each component of the property-local design runs and what it does
ComponentWhere it runsWhat it does
InitiatorMaxLinear SoC APs and switches in rooms and common areasStarts each tenant’s tunnel; APs also run the AP-side digital twin
UnderlayPatch panels and stacked switchesCarries every tenant on one NAT-free path
ConcentratorBlueField-3 DPU at the property headendMaps each tenant to its vGW and supplies telemetry
vGWThe on-site concentratorApplies the tenant’s firewall, NAT, bandwidth policy and public IP
rXg controllerx86-64 server at the propertyDirects initiators and concentrators; handles policy and billing
Fleet ManagerA central rXg or high-availability pairTemplates, upgrades and encrypted site backups
AI diagnosticsNVIDIA Blackwell GPUs on the operator’s premisesInterprets AP tests and DPU telemetry, off the forwarding path
BreakoutThe property, over two DIA uplinksEach tenant exits from its own public IP

When to choose it

The property owns its Ethernet

Outlets reach switches the operator controls. An apartment property can run its concentrators on site.

Residential

Large sites host their own

An office tower or large campus can run its own concentrators. Smaller buildings share regional ones.

Commercial real estate

Education

Demand or standards are site-specific

A venue sizes on-site concentrators for peak attendance. Cost per room and brand standards shape hotel designs; a flagship resort can host its own gateway and controller.

Venues and transit

Hospitality

Resilience

Two DIA uplinks

The rXg fails over between them. The property view shows the state of each.

Separate metro routes

Separately engineered paths reach distinct metros.

A clustered site node

The property’s rXg can run as a cluster. Fleet Manager backups restore a node after a hardware failure.

Operating headroom

The capacity model’s 75% ceiling leaves headroom. Failover depends on placement and recovery design.

Sizing

On-site concentrators are sized for the property’s subscribers. Our model assumes 8,000 per DPU at raw capacity, or 6,000 at the 75% ceiling.

Planned 2U to 5U servers hold one to eight DPUs. Mixed DPU and GPU configurations need OEM validation.

National capacity model

DPU server plans

What your pilot proves

Before the pilot, we agree on acceptance criteria and mark each element supported, assumed or awaiting validation.

The underlay

We check switch models, firmware and MTU, and confirm the path has no NAT.

Failover

We agree failure tests with you before the pilot.

Capacity and operations

We benchmark the target server and run Fleet Manager templates and upgrades.

The acceptance report compares lab and field results with the criteria. You decide whether to roll out.

How pilots work

Plan gateways for your properties

We review your properties, subscriber targets and uplinks, then deliver a dated, versioned reference design.