Property-local
Every tenant’s gateway runs on site
On a property that controls its own Ethernet, MaxLinear initiators reach NVIDIA BlueField-3 DPU concentrators in the building. Those concentrators host each tenant’s virtual gateway (vGW).
How traffic flows
Traffic stays on the property until the last step.
-
Device to initiator
A phone joins a MaxLinear SoC access point (AP) shared by many tenants.
-
Into the tenant’s tunnel
The AP encapsulates the phone’s traffic. In a VXLAN deployment, each tenant has its own VXLAN network identifier (VNI).
-
Across property Ethernet
Patch panels and stacked switches carry it, with no NAT.
-
Into the concentrator
A BlueField-3 DPU at the property headend terminates the tunnel.
-
Through the tenant’s vGW
The vGW applies the tenant’s firewall, NAT, bandwidth policy and public IP.
-
Out to the Internet
It leaves on one of two dedicated Internet access (DIA) uplinks.
Why the private path matters
With no NAT on the path, GRE works naturally. On spine-leaf fabrics that need equal-cost multipath, VXLAN’s load distribution may justify its extra overhead.
Where the operator controls the switches, raising their MTU to 1,550 bytes keeps a full 1,500-byte inner packet under either protocol.
VXLAN versus GRE (white paper)What runs where
| Component | Where it runs | What it does |
|---|---|---|
| Initiator | MaxLinear SoC APs and switches in rooms and common areas | Starts each tenant’s tunnel; APs also run the AP-side digital twin |
| Underlay | Patch panels and stacked switches | Carries every tenant on one NAT-free path |
| Concentrator | BlueField-3 DPU at the property headend | Maps each tenant to its vGW and supplies telemetry |
| vGW | The on-site concentrator | Applies the tenant’s firewall, NAT, bandwidth policy and public IP |
| rXg controller | x86-64 server at the property | Directs initiators and concentrators; handles policy and billing |
| Fleet Manager | A central rXg or high-availability pair | Templates, upgrades and encrypted site backups |
| AI diagnostics | NVIDIA Blackwell GPUs on the operator’s premises | Interprets AP tests and DPU telemetry, off the forwarding path |
| Breakout | The property, over two DIA uplinks | Each tenant exits from its own public IP |
When to choose it
The property owns its Ethernet
Outlets reach switches the operator controls. An apartment property can run its concentrators on site.
Large sites host their own
An office tower or large campus can run its own concentrators. Smaller buildings share regional ones.
Demand or standards are site-specific
A venue sizes on-site concentrators for peak attendance. Cost per room and brand standards shape hotel designs; a flagship resort can host its own gateway and controller.
Resilience
Two DIA uplinks
The rXg fails over between them. The property view shows the state of each.
Separate metro routes
Separately engineered paths reach distinct metros.
A clustered site node
The property’s rXg can run as a cluster. Fleet Manager backups restore a node after a hardware failure.
Operating headroom
The capacity model’s 75% ceiling leaves headroom. Failover depends on placement and recovery design.
Sizing
On-site concentrators are sized for the property’s subscribers. Our model assumes 8,000 per DPU at raw capacity, or 6,000 at the 75% ceiling.
Planned 2U to 5U servers hold one to eight DPUs. Mixed DPU and GPU configurations need OEM validation.
What your pilot proves
Before the pilot, we agree on acceptance criteria and mark each element supported, assumed or awaiting validation.
The underlay
We check switch models, firmware and MTU, and confirm the path has no NAT.
Failover
We agree failure tests with you before the pilot.
Capacity and operations
We benchmark the target server and run Fleet Manager templates and upgrades.
The acceptance report compares lab and field results with the criteria. You decide whether to roll out.
How pilots workOther designs
Plan gateways for your properties
We review your properties, subscriber targets and uplinks, then deliver a dated, versioned reference design.